Flameproof motor YBX3 series

Characteristics

AC/DC
three-phase
Type
asynchronous
Voltage
660 V
Protection class
explosion-proof, flameproof
Configuration
squirrel cage, small
Number of poles
4-pole, 6-pole, 8-pole, 10-pole, 2-pole
Applications
blower, for household appliances, for the mining industry, for hydraulic applications, for marine applications
Other characteristics
high-efficiency, low-noise, low-vibration
Power

Max.:  315 kW
(428.281 hp)

Min.:  0.75 kW
(1.02 hp)

Intensity

Max.:  549 A

54.9 A

Min.:  1.72 A

Torque

Max.:  2.8 Nm
(2.0652 ft.lb)

2 Nm
(1.4751 ft.lb)

Min.:  1.6 Nm
(1.1801 ft.lb)

Rotational speed

Max.:  2,980 rpm
(18,723.89 rad.min-1)

980 rpm
(6,157.52 rad.min-1)

Min.:  592 rpm
(3,719.65 rad.min-1)

Diameter

Max.:  355 mm
(13.98 in)

200 mm
(7.87 in)

Min.:  80 mm
(3.15 in)

Operating temperature

Max.:  40 °C
(104 °F)

25 °C
(77 °F)

Min.:  15 °C
(59 °F)

Description

The YBX3 series high efficiency flameproof three-phase asynchronous motor is a series of self sealing fans, fan fans, squirrel cage and high efficiency flameproof three phase induction motors developed by our company. The efficiency conforms to the 2 level energy efficiency of GB18613-2012 “small and medium three phase asynchronous motor energy efficiency limits and energy efficiency grades”, and has the characteristics of excellent performance, safe and reliable use, vibration and noise reduction compared with the similar products, which is in line with environmental protection requirements. The explosion-proof performance of this series of motors is consistent with GB3836.1-2010’s explosive environment first parts: General requirements for equipment and GB3836.2-2010, the second part of explosive environment: the flameproof type is made by the provisions of the device protected by flameproof enclosure “d”. The explosion-proof marks are Ex D II A T4 Gb, Ex D II B T4 Gb, Ex D II.

A place for the existence of an explosive gas mixture.

Ex D II A T4 Gb is suitable for factory II a, and the temperature group is mixed with explosive gas in T1, T2, T3 and T4 groups.

The environment in which the compound exists.

Ex D II B T4 Gb is suitable for factory IIB, and the temperature group is mixed with explosive gas in T1, T2, T3 and T4 groups.

Three

The environment in which the compound exists.

Ex D II C T4 Gb is suitable for factory IIC, and the temperature group is mixed with explosive gas in T1, T2, T3 and T4 groups.

The environment in which the compound exists.

Share this article